![]() Hiện chưa có sản phẩm |
TỔNG TIỀN: | 0₫ |
Xem giỏ hàng | Thanh toán |
Electronics module f. ET200 PRO, 4 AI TC High Feature, TC type B, E, J, K, L, N, R, S,T Voltage +/-80 mV, Channel diagnostics, incl. bus module, Connection module IO 6ES7194-4..00-0AA0 order separately
Note: The Connection module IO 6ES7194-4..00-0AA0 needs to be ordered separately.
Additional Information
Support | Technical Data | Manuals / Links |
FEATURE | VALUE |
Number of HW-interfaces RS-232 | 0 |
Supporting protocol for PROFINET IO | false |
Supporting protocol for SUCONET | false |
Radio standard WLAN 802.11 | false |
Supporting protocol for PROFIBUS | false |
Appendant operation agent (Ex ib) | false |
Input, current | false |
Supporting protocol for INTERBUS-Safety | false |
Voltage type (supply voltage) | DC |
Supporting protocol for KNX | false |
Supporting protocol for SERCOS | false |
Number of HW-interfaces industrial Ethernet | 0 |
Supporting protocol for SafetyBUS p | false |
Input, thermocouple | true |
Supporting protocol for ASI | false |
Number of HW-interfaces other | 0 |
Wall mounting/direct mounting | true |
Supporting protocol for LON | false |
Supporting protocol for PROFINET CBA | false |
Supporting protocol for PROFIsafe | false |
Supporting protocol for Data-Highway | false |
Input signal, configurable | true |
Supporting protocol for AS-Interface Safety at Work | false |
Rack-assembly possible | false |
Supply voltage DC | 20.4 V |
Radio standard UMTS | false |
Number of HW-interfaces USB | 0 |
Number of analogue outputs | 0 |
Input, voltage | true |
Supporting protocol for other bus systems | false |
Supporting protocol for TCP/IP | false |
Number of HW-interfaces parallel | 0 |
Supporting protocol for DeviceNet Safety | false |
Width | 45 mm |
Input, resistor | false |
Radio standard GSM | false |
Rail mounting possible | true |
Appendant operation agent (Ex ia) | false |
Supporting protocol for EtherNet/IP | false |
Suitable for safety functions | false |
System accessory | true |
Supporting protocol for INTERBUS | false |
Supporting protocol for Modbus | false |
Radio standard Bluetooth | false |
Height | 130 mm |
Fieldbus connection over separate bus coupler possible | true |
Number of HW-interfaces serial TTY | 0 |
IO link master | false |
Front built-in possible | true |
Supply voltage DC | 28.8 V |
Analogue inputs configurable | true |
Depth | 35 mm |
Resolution of the analogue inputs | 15 Bit |
Number of HW-interfaces wireless | 0 |
Input, resistance thermometer | false |
Number of interfaces PROFINET | 0 |
Number of analogue inputs | 4 |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for CAN | false |
Number of HW-interfaces RS-422 | 0 |
Radio standard GPRS | false |
Supporting protocol for DeviceNet | false |
Number of HW-interfaces RS-485 | 0 |